Email Us
FALCO™ Embolization Assist Stent

FALCO™ Embolization Assist Stent Overview

falco embolization assist stent

DFT Intracranial Stent with Blue-Shield Surface Technology

FALCO™ Embolization Assist Stent Features

Available in large-diameter configurations(4.5 mm and 5.5 mm)with extended lengths of 50 mm and 75 mm,enabling treatment of long-segment dissecting lesions

Available in large-diameter configurations(4.5 mm and 5.5 mm)with extended lengths of 50 mm and 75 mm,enabling treatment of long-segment dissecting lesions

Resheathable and repositionable prior to 90%deployment,allowing repeated retrieval and precise adjustment before final release

resheathable-and-repositionable-prior-to-90-deployment.jpg

  • 5mm Radiopaque Distal Delivery Wire Tip

  • Pre-shaped 90°distal tip,re-shapable as needed toaccommodate procedural preference

  • The distance between the recapture marker and deployment  marker on the delivery system is 1.5mm

  • Repeated resheathing and repositioning are possible as long  as the stent is not deployed beyond the recapture marker


resheathable-and-repositionable-prior-to-90-deployment-2.png

Ordering Information of FALCO™ Embolization Assist Stent

SPECIFICATIONSUnconstrainedouter diameter(mm)Recommended Vessel Diameter(mm)Stent Length in the nominal diameter B1 (mm)Stent Length in the Minimum Vessel B2 (mm)Microcatheter tenimengtveisel
Compatibility(ID)
VRD-25-102.72.0-2.510130.017"
VRD-25-151519
VRD-25-202027
VRD-25-252533
VRD-35-153.72.5-3.515250.021”
VRD-35-202033
VRD-35-252542
VRD-35-353556
VRD-40-154.23.0-4.01528
VRD-40-202035
VRD-40-252543
VRD-40-353559
VRD-45-154.73.54.51526
VRD-45-202034
VRD-45-252545
VRD-45-353556
VRD-45-5050850.027"
VRD-45-7575128
VRD-55-155.74.5-1524
VRD-55-202034
VRD-55-252546
VRD-55-353560
VRD-55-505086
VRD-55-7575130




falco-intracranial-stent.png


DFT Intraluminal Support Device for Coil Embolization of Intracranial Aneurysms


  • Constructed with DFT braided alloy wires

  • Optimized filament diameter to balance flexibility and radial support

  • Increased braiding wires in larger diameter sizes to maintain structural integrity

  • Designed to accommodate tortuous internal carotid segments and complex vascular anatomy

  • Suitable for distal and bifurcation aneurysms, ruptured and blister-type aneurysms, as well as long-segment dissecting lesions


Braided with DFT(platinum-cored nitinol)alloy wires for full-strand radiopacity

  • Enhanced intra-procedural assessment of stent expansion and wallapposition

  • 4 radiopaque markers at both proximal and distal ends to facilitate precise positioning

Braided with DFT(platinum-cored nitinol)alloy wires for full-strand radiopacity

Optimized braided design to facilitate smooth expansion within tortuous internal carotid segments

  • 0.5 mm flared ends (shorter than typical 2mm designs), reducing the non-functional segment and supporting enhanced procedural safety

  • Larger diameters(4.0-5.5mm)incorporate 20-24 braided wires to enhance structural support and promote reliable expansion in tortuous anatomy

Optimized braided design to facilitate smooth expansion within tortuous internal carotid segments

Blue-Shield Thermally Oxidized Surface

  • Blue-Shield thermall oxidized surfaceforms a dense titanium dioxide layer that reduces nickelion release and platelet adhesion, supporting improved hemocompatibility and lower thrombus risk

Blue-Shield Thermally Oxidized Surface

2.5 mm configuration deliverable through a 0.017 inch microcatheter, supporting access to distal vascular lesions

  • 2.5mm diameter(lengths 10/15/20/25mm) deliverable through a 0.017"microcatheter, supporting access to distal vascular lesions

  • 3.5-4.5mm diameters compatible with 0.021" microcatheter systems

  • 4.5-5.5mm diameters deliverable through 0.027" microcatheters

2.5 mm configuration deliverable through a 0.017 inch microcatheter, supporting access to distal vascular lesions

20% metal coverage to provide enhanced scaffolding support for dense coil embolization

  • Designed to support coil stabilization during embolization, helping to reduce the risk of coil protrusion into the parent vessel

  • Particularly suited for wide-neck, ruptured, and blister-type aneurysms

  • Finer braid filament diameter (0.05mm) compared with conventional 0.06mm braided configurations

  • Increased mesh density at nominal diameter contributes to enhanced scaffold support


20% metal coverage to provide enhanced scaffolding support for dense coil embolization

High Conformability Enables Controlled Compaction and 'Lantern' Technique Applications

  • The lantern techniqyue may increase metal coverage at the aneurysm neck to provide protection in bifurcation lesions

  • It supports effective coil embolization and, in selected cases, may reduce the need foran additional stent compared with dual-stent strategies

Providing Comprehensive Solutions for Patients Worldwide

E-mail:
info@zyloxtb.com
Phone:
+86-571-8861-0082
Add:
Zylox-Tonbridge Industrial Park, No. 270 Shuyun Road, Yuhang District, Hangzhou, Zhejiang, China
Zylox-Tonbridge Industrial Park, No. 270 Shuyun Road, Yuhang District, Hangzhou, Zhejiang, China
info@zyloxtb.com +86-571-8861-0082
We use cookies on this site, including third party cookies, to delivery experience for you.
Accept Cookies
Read Privacy Policy