OVERVIEW
Dayv™ Balloon Guide Catheter

Dayv™ Balloon Guide Catheter is indicated for use in facilitating the insertion and guidance of an intravascular catheter into a target blood vessel. The balloon provides temporary vascular occlusion during these and other angiographic procedures. The Balloon Guide Catheter is also indicated for use as a conduit for Retrieval devices.

Dayv™ Balloon Guide Catheter

DAYV™ BALLOON GUIDE CATHETER FEATURES

  • Features a stainless steel hybrid braided shaft for enhanced support and structural integrity

  • Designed to establish a stable, large-lumen vascular access pathway, facilitating efficient device delivery and proximal flow control

  • Ultra-soft distal segment minimizesvessel wall irritation

  • Flexible initial section of the distal segment

  • Flexible mid-distal shaft enhances navigation through tortuous anatomy

  • Flexible initial section of the distal segment

  • Seamless mid-shaft transition for smooth and atraumatic navigation

  • Reinforced proximal shaft enhances aortic arch support and minimizes intraprocedural device displacement

KEY STEPS OF DAYV™ BALLOON GUIDE CATHETER

1. Establish a triaxial system (balloon guide catheter, large-bore intermediate catheter, microcatheter)

2. Deploy the long stent retriever in the distal vessel ( M2 branch of the MCA inferior trunk)

3. Release the stent retriever

4. Withdraw the microcatheter

5. Advance the intermediate catheter over the stent retriever wire

6. Release the tension on the stent retriever wire

7. Inflate the balloon guide catheter and perform simultaneous apiration at both proximal and distal sites

8. Retrieve the stent–intermediate catheter ensemble as a unit

ORDERING INFORMATION OF DAYV™ BALLOON GUIDE CATHETER


Specification

Outer

Diameter

(mm/inch)

Internal

Diameter

(mm/inch)

Usable

Length

(cm)

Rated Balloon

Inflation Volume

(mL)

Balloon

Length

(mm)

Balloon

Diameter

(mm)

0.6

10.0

10.0

BGC6085A/B6.0F(2.00/0.079)1.39/0.05585

BGC6090A/B

6.0F(2.00/0.079)

1.39/0.055

90

BGC6095A/B

6.0F(2.00/0.079)

1.39/0.055

95

BGC6385A/B

6.3F(2.20/0.087)

1.50/0.059

85

BGC6390A/B

6.3F(2.20/0.087)

1.50/0.059

90

BGC6395A/B

6.3F(2.20/0.087)

1.50/0.059

95

BGC7085A/B

7.0F(2.43/0.096)

1.78/0.070

85

BGC7090A/B

7.0F(2.43/0.096)

1.78/0.070

90

BGC7095A/B

7.0F(2.43/0.096)

1.78/0.070

95

BGC7385A/B

7.3F(2.50/0.098)

1.90/0.075

85

BGC7390A/B

7.3F(2.50/0.098)

1.90/0.075

90

BGC7395A/B

7.3F(2.50/0.098)

1.90/0.075

95

BGC8085A/B

8.0F(2.76/0.109)

2.24/0.088

85

BGC8090A/B

8.0F(2.76/0.109)

2.24/0.088

90

BGC8095A/B

8.0F(2.76/0.109)

2.24/0.088

95

BGC8385A/B

8.3F(2.80/0.110)

2.31/0.091

85

BGC8390A/B

8.3F(2.80/0.110)

2.31/0.091

90

BGC8395A/B

8.3F(2.80/0.110)

2.31/0.091

95

BGC9085A/B

9.0F(3.00/0.118)

2.44/0.096

85

BGC9090A/B

9.0F(3.00/0.118)

2.44/0.096

90

BGC9095A/B

9.0F(3.00/0.118)

2.44/0.096

95